Items Required for Installation
Tools:
Drill, drill bits, Screwdriver, tube cutter, adjustable wrench, Phillips Offset
Screwdriver, and vinyl gloves .
Parts not included in package:
Inlet shut off valve, PTFE Thread Sealant Tape, 1/4 inch O.D. tubing,
additional 3/8 inch O.D. tubing and mounting screws.
Installation Location
For your convenience, the Ultrefiner II bracket assembly is designed to be
mounted on either side of the cabinet, with the tubing ports pointing to
the back.
Kitchen Sink Installation
Systems being mounted under a kitchen sink require an air gap faucet. See
figure 3.
Wall Mount or Other
Systems being mounted in different location than under a kitchen sink
can use a non air gap faucet with the drain line connecting to a separate
air gap device.
!
Important Notes:
The tubing used for installation must be of
food grade type. John Guest or Parker brand
tubing is recommended for their compatibility
with the fittings on your system.
STORAGE TANK
REVERSE OSMOSIS
MOUNTED
UNDER SINK
INLET VALVE
CONNECTED TO
COLD WATER LINE
Figure 3
1/2 " DRAIN LINE
FLOOR DRAIN
GAP-A-FLOW AIR GAP
"Mr. Drain"
AIR GAP
STAND PIPE
FOR
WASHER,
DRAIN
STACK
AIR GAP - floor drain
AIR GAP - Mr. Drain
AIR GAP - Wall Mount
FAUCET WITH
AIR GAP
DRAIN
CONNECTION
FROM AIR GAP
FAUCET
ALL TUBING RUNS TO
BACK OF CABINET