1. Safety Precautions
• To prevent accidents and/or injuries, do not hoist the equipment
over your shoulder; use a hand truck.
• Do not lay the system on its side.
Wear safety glasses and work gloves during installation and
service.
2. Test the Raw Water
• If water contains iron, manganese or copper more than its appli-
cation limitations (see page 5), a seperate removal system is
suggested to be installed prior to the RainSoft Centurion system,
consulting with your local dealer.
3. Check the Water Pressure
The minimum water pressure is 15 psi and the maximum water
pressure is 100 psi. Use a pressure gauge to confirm that the water
pressure does not exceed 100 psi. If the water pressure does exceed
this limit, install a pressure regulator on the inlet pipe to the
system. Set the pressure regulator at a maximum of 60 psi, which
is the optimum operating pressure.
4. Locate a Site for the System
There is only one requirement needed for a site: the main water
source. Locate the system as close to the water meter or pressure
tank as possible.
Place the system in the desired location. The location must have a
level, smooth, and clean surface.
If the system is located outdoors, protect the unit from direct
sunlight; direct sunlight can damage the fiberglass and other
system components. If necessary, build a box or shed.
5. Turn Off the Water and Drain the Plumbing
• Turn off the water at the meter or pressure tank.
Drain all the pipes. Do not sweat pipes with water in them; steam
will damage the plastic parts in the valve.
• To drain the plumbing system, open all faucets in the house and
flush the toilets. The water will drain out of the lowest faucet or
outlet and air will enter the plumbing system.
7
Important Note: The system can only be
installed outdoors in climates that do
not reach freezing levels.
!
For Massachusetts Residents Only:
The Commonwealth of Massachusetts
Plumbing Code 248 CMR shall be
adhered to. A licensed plumber shall be
used for this installation
Installation Instructions continued from page 6.